LibCorpus
Back to Papers

Entanglement-Enhanced Optical Ion Clock

Kai Dietze et al.

Fig. 2, panel (1)

Contrast of measurement signal against interrogation time (ms) for enDFS (red), ccDFS (blue) and single-ion Ramsey (black), with error bars. Dash-dotted and dotted curves are the lifetime-limited contrast for enDFS and ccDFS; the black curve is a Gaussian noise model. The printed axis break between about 4 and 50 ms is not kept, and the open ccDFS marker at 3.5 ms is drawn filled.

Files

Provenance

This panel was computed from the authors' public data deposit (Zenodo: https://doi.org/10.5281/zenodo.15705557, CC BY 4.0), with the single-ion Ramsey points and the model curves recovered from the published vector figure. The plot shown here is re-rendered for interactive viewing and analysis. See the paper for the original figure and full scientific context.

License: CC BY 4.0.

Phys. Rev. Lett. 136, 073601 (2026) · DOI: 10.1103/dyqm-k8p6 · arXiv: 2506.11810

All figures of this paper

All papers · About · Statistics · Submit data · API