Miniaturized magnetic-field sensor based on nitrogen-vacancy centers
Fig. 12, panel (a)
Measured and shot-noise-limited (SN lim.) sensitivity (T/$\sqrt{\mathrm{Hz}}$) against effective sensing volume $l_{\mathrm{eff}}$ (mm), from the diamond or, if defined, the sensing volume, on log-log axes, each point labelled with its reference number as printed. The solid line is the volume-dependent shot-noise sensitivity.
Files
- Data: data.csv
- Overlay (theory: Vol. depend. SN sensitivity): overlay.csv
Provenance
This panel was computed from the authors' public data deposit (Zenodo: https://doi.org/10.5281/zenodo.16410952, CC BY 4.0), with the volume-dependent shot-noise line recovered from the vector figure deposited with the data. The plot shown here is re-rendered for interactive viewing and analysis. See the paper for the original figure and full scientific context.
License: CC BY 4.0.
Phys. Rev. Appl. 24, 054078 (2025) · DOI: 10.1103/lbqj-d5zv · arXiv: 2402.19372