LibCorpus
Back to Papers

Microwave-free imaging magnetometry with nitrogen-vacancy centers in nanodiamonds at near-zero field

Saravanan Sengottuvel, Omkar Dhungel, Mariusz Mrózek, Arne Wickenbrock, Dmitry Budker, Wojciech Gawlik, Adam M. Wojciechowski

Fig. 3, panel (2)

Map of the zero-field-feature contrast $C$ (%) over X and Y ($\mu$m) at 0.5 A, current path 3 to 4, the middle map of the printed first row. The black horizontal line marks the pixel row of the line cuts below.

Files

Provenance

This panel was reproduced from the authors' public data deposit (Zenodo: https://doi.org/10.5281/zenodo.14833488, CC BY 4.0). The plot shown here is re-rendered for interactive viewing and analysis. See the paper for the original figure and full scientific context.

License: CC BY 4.0.

Phys. Rev. Appl. 23, 034001 (2025) · DOI: 10.1103/PhysRevApplied.23.034001 · arXiv: 2409.02199

Other panels of Fig. 3: (1) (3) (4) (5) (6)