Quantum sensing with spin defects in boron nitride nanotubes
Roberto Rizzato, Andrea Alberdi Hidalgo, Linyan Nie, Elena Blundo, Nick R. von Grafenstein, Jonathan J. Finley, Dominik B. Bucher
Fig. 3, panel (b)
Normalized contrast against pulse sequence duration T ($\mu$s, log scale) for a Hahn echo (1 $\pi$-pulse) and CPMG sequences with 2 to 1028 $\pi$-pulses: eleven measured series, each with its dotted stretched-exponential fit (parameters from the paper's Table 1).
Files
- Data: data.csv
- Overlay (theory: 1 $\pi$-pulse, 2 $\pi$-pulses, 4 $\pi$-pulses, 8 $\pi$-pulses, 16 $\pi$-pulses, 32 $\pi$-pulses, …): overlay.csv
Provenance
This panel was computed from the authors' public data deposit (Zenodo: https://doi.org/10.5281/zenodo.17700056, CC BY 4.0). The plot shown here is re-rendered for interactive viewing and analysis. See the paper for the original figure and full scientific context.
License: CC BY 4.0.
Nat. Commun. 16, 11333 (2025) · DOI: 10.1038/s41467-025-67538-2 · arXiv: 2504.16725
Other panels of Fig. 3: (a) (b-inset)