Integrated microcavity electric field sensors using Pound-Drever-Hall detection
Fig. 3, panel (c)
Linearity of the sensors: sensor response at 100 MHz (dBm) against applied electric field (dB$\mu$V/m) for Device 1 and Device 2 with the ECDL (red and blue circles) and Device 1 with the fiber laser (pink squares), with linear fits (black; dashed for the fiber laser) and the dashed noise-floor line. The broken y axis of the print is shown continuous.
Files
- Data: data.csv
Provenance
This panel was reproduced from the authors' public data deposit (Nature Communications Source Data: https://doi.org/10.1038/s41467-024-45699-w, CC BY 4.0), with the noise-floor line recovered from the published vector figure. The plot shown here is re-rendered for interactive viewing and analysis. See the paper for the original figure and full scientific context.
License: CC BY 4.0.
Nat. Commun. 15, 1386 (2024) · DOI: 10.1038/s41467-024-45699-w