Room-temperature control and electrical readout of individual nitrogen-vacancy nuclear spins
Fig. 1, panel (b-1)
Current (pA, log axis) against bias voltage (V) for the single NV centre: total current with the laser focused on the NV (red), background current with the laser focused outside the NV (blue) and dark current with the laser off (grey). The dotted line marks the selected 8.6 V. The print draws smoothed curves; the measured values are joined by straight lines here.
Files
- Data: data.csv
Provenance
This panel was reproduced from the authors' public data deposit (figshare: https://doi.org/10.6084/m9.figshare.14748138, CC BY 4.0). The plot shown here is re-rendered for interactive viewing and analysis. See the paper for the original figure and full scientific context.
License: CC BY 4.0.
Nat. Commun. 12, 4421 (2021) · DOI: 10.1038/s41467-021-24494-x